Server Rooms & IT Systems
SECTOR 02: MISSION-CRITICAL IT INFRASTRUCTURE

Fire Defense for Server Rooms & Data Centers

Review specifications and engineering applications for enterprise server racks, telecom rooms, and high-voltage electrical panels. Non-conductive clean agent liquid gas engineered to eliminate corrosive particulate residue on sensitive microcircuits and enterprise hard drives.

100 kV
Non-Conductive Rating
0%
Circuit Residue
SUS 304
ASME Pressure Vessel
INFRASTRUCTURE RISK ASSESSMENT

Why Conventional Powder or CO2 Threatens Server Uptime

In server environments, the choice of fire extinguisher directly governs equipment survival. Using the wrong medium transforms a contained electrical short into a multi-million-dollar disaster.

RISK 01

Chemical Powder Circuit Corrosion

Dry chemical powder acts as an abrasive, corrosive salt. When ingested by cooling fans into server chassis, it melts onto heated microprocessors, permanently shorting printed circuit boards (PCBs).

RISK 02

CO2 Cold Shock & HDD Failure

Carbon Dioxide discharges at -78°C. This extreme thermal drop creates rapid thermal contraction shock, cracking silicon chips and inducing physical acoustic shock waves that permanently crash spinning magnetic hard drives.

RISK 03

Operator Suffocation Hazards

CO2 functions by oxygen displacement, presenting lethal asphyxiation risks to network engineers trapped in confined server rooms. Clean Agent extinguishes fires chemically without dropping room oxygen levels.

ENGINEERED ADVANTAGES

Engineered Safety for Mission-Critical Electronics

01 // DIELECTRIC

Non-Conductive

Certified safe on live energized electrical equipment up to 100,000 Volts without risk of electrical arc flash or shock to personnel.

02 // RESIDUE-FREE

Zero Collateral Ruin

Completely evaporates without leaving conductive, acidic, or sticky coatings on motherboard components, ribbon cables, or optical transceivers.

03 // GENTLE COOLING

No Thermal Shock

Unlike cryogenic CO2 (-78°C), clean liquid gas absorbs heat gradually through chemical endothermic reaction without fracturing hot silicon chips.

04 // DURABILITY

SUS 304 Vessels

ASME 'U' & 'R' compliant Stainless Steel construction guarantees zero internal scale or rust flakes contaminating precision equipment.

ZONE SPECIFICATIONS

Recommended Units for Critical IT Infrastructure

CORE SERVER ROOM UNIT
RACK ROWS & NOC ROOMS

Star Pro Business 3KG

Stainless SUS 304 Clean Agent

  • • Optimal balance of discharge duration (14-18s) and maneuverability
  • • Suppresses rack cable harness and PDU electrical short fires
  • • Zero corrosive residue on adjacent enterprise servers
  • • Non-conductive formula safe for live energized operations
SPECIFY SERVER UNITS ›
MAIN DISTRIBUTION & TRANSFORMERS

Star Heavy Facility 6KG

Heavy-Duty Clean Liquid Gas

  • • High-capacity output with extended 5-7 meter discharge range
  • • Rapid knockdown of high-voltage arc fires in LV/HV switchboards
  • • Leaves zero conductive powder on circuit breaker mechanisms
  • • 3-year warranty with zero recurring maintenance downtime
SPECIFY SWITCHBOARD UNITS ›
UNATTENDED RACKS & UPS VAULTS

Star Auto-Ceiling Capsule

Autonomous Thermal Bulb 68°C Module

  • • Autonomous 24/7 activation upon ambient temperature exceeding 68°C
  • • Instant volumetric total flooding of enclosed server cabinets
  • • Requires no human intervention or electrical power to trigger
  • • Prevents catastrophic thermal runaway spread across battery UPS rooms
SPECIFY AUTO CAPSULE ›
ENTERPRISE IT SAFETY CONSULTATION

Protect Your Enterprise IT Infrastructure Against Fire Downtime

Speak with our certified fire engineering consultants to evaluate server room cubic volumes, airflow dynamics, and optimal clean agent cylinder configurations.

CONNECT WITH IT DEFENSE SPECIALIST ›